One amplifier, six sound wave vibrators, a set of wiring harnesses, a mobile mini program, and control for one seat. The installation position of each seat oscillator is at the thigh (near the knee), waist, back, and can also be at the thigh (near the knee), between the waist and back, or at the shoulder. It can be customized according to the user's height.
A power amplifier, eight sound wave vibrators, a set of wiring harness, and a mobile phone app to control a seat. It is preferably equipped with a leg rest for calf massage, with installation positions at the calves, thighs (near the knees), waist, and back; alternatively, positions can be at the thighs (near the knees), waist, back, and shoulders, allowing personalized adjustment according to the user's height.
4D cinema mode:Upgrades every 2D movie to a 4D movie;; Car owners have their own private 4D cinema, where family, lovers, and friends can watch 4D movies together:
Game mode:Immersive gaming, boxing to the point of flesh! Gun shock!
Music mode:Listening to music is like attending a concert live!
Sound wave vibration promotes blood circulation and assists in detoxification of the body;
Quickly enter a deep sleep state in 3 minutes through physical means;
Quickly calm people's emotions and regulate their mood;
When driving, beat the user's waist and back to refresh the driver's mind;
(1) According to the testing instructions, set the vibration frequency and voltage. Long vibration at the highest gear, record the duration. (Destructive testing, for reference only)
(2) Designated playlist (see attachment). Music mode long vibration, tested at 1000H
(3) According to the testing instructions, set the vibration frequency and voltage. Work for 30 minutes and rest for 15 minutes in the highest gear mode. Test for 1000H
1. Stage 1 Preliminary Pollution:
a) Salt spray conditions: 35 ± 3 ℃, 5 ± 0.1% NaCl solution, pH value: 6.5~7.2
b) Spray for 2 hours, then stand still for 1 hour, the entire process of the specimen working mode MDF1.2
c) Dry at 35 ± 3 ℃ for 12 hours.
2. Stage 2: High temperature and humidity aging.
a) Test temperature: Low temperature -40 ± 3 ℃, high temperature 85 ± 3 ℃
b) Temperature change rate: 5 ℃/min;
c) Low temperature holding time: 20 minutes;
d) High temperature holding time: 40 minutes;
e) In each cycle, the last 5 minutes of low temperature and the phase from 23 ℃ to high temperature and holding end. During this period, the 14V power supply operates in MDF3.2 mode, while the remaining time operates in MDF3.1 mode;
f) Cycle times: 500.
a) Dust type: Arizona powder, dust density: 2kg/m2;
b) Each cycle: for a single cycle of 20 minutes, turn on the dust circulation switch at 4 minutes and 55 seconds, hold for 5 seconds, and keep the dust circulation switch closed at other times. During the test, the working mode of the specimen is MDF1.2;
c) Cycle times: 20;
d) Meet IP5KX requirements